1. Mechanical Structure (Dimensions & Assembly)
Main Housing Cavity
Integrally injection-molded rectangular enclosure (420mm × 160mm × 95mm). Φ6 mounting through-holes at four corners support wall mounting and portable carrying. Cuts customers' costs of stocking multiple specifications.
Handle Assembly
Integrated solid PP handle on the left, fastened with M4 A2 stainless steel screws. Passes static 35kg tensile load testing. Resists fracture during frequent transportation, eliminating spare parts replacement.
Isolated Protection Compartment
Independent circuit breaker chamber with lockable transparent PC window. Insulating partition separates live zone and socket output zone (clearance ≥12mm). Visual check without powering down boosts maintenance efficiency.
Output Socket Layout
3 IEC60309 socket bases arranged horizontally (92mm spacing). Secured by M3 stainless steel screws with full-circle silicone water-stop gaskets. Simultaneous tool operation without interference; sealing blocks mud and water ingress.
Cable Entry Port
PG16 nylon waterproof cable gland on the right. Triple-layer rubber sealing ring structure compatible with outer diameter 10–14mm cables. Fits most standard cables, removing the need for transition adapters.
Pre-assembled Input Wiring Harness
Factory-pre-wired flexible rubber cable (2 meters in length) with copper terminals crimped at the ends and secured to the busbar; the cable sheath features continuous printed markings. Ready for plug-and-play installation upon delivery, saving on-site manual wiring time and labor.
Input Connector
Blue IEC60309 16A 2P+E industrial male plug, color-coded for AC 200–250V single-phase circuits. Globally universal standard interface matches most European/American generators, maximizing cross-equipment compatibility.
2. Electrical Operating Principle (Circuit & Metrics)
- Main Circuit Topology: Single-phase L+N+PE 3-wire main input, with 3 parallel branch outputs for sockets. The independent multi-load power supply architecture allows simultaneous operation of multiple handheld power tools.
- Overload & Short-Circuit Protection Logic: Each socket branch has an independent 16A C-curve MCB. Branch current at 1.13×In (18.08A) triggers delayed thermal tripping (>1 hour). Instantaneous current ≥10×In (160A) cuts off the single branch within 0.01s. Single branch faults will not disconnect remaining sockets, preventing full-site work stoppage.
- Continuous Earthing Conduction Principle: Uninterrupted PE wire runs through the earth pin of the input plug, metal mounting studs, and terminals to form an equipotential bonding loop. Complete earthing loop DC resistance measures ≤0.1Ω, delivering stable protection for damp or rainy sites, avoiding accidents and shutdown fines.
- Optional Residual Current Protection Branch: A 30mA Type A RCD can be installed on the main incoming busbar. When leakage current ≥30mA, the unit cuts off all L/N power within 40ms while keeping the PE earthing path intact. Complies with mandatory EU construction leakage safety regulations to pass third-party safety inspections.
- Insulation Coordination Specifications: Rated insulation voltage 450/750V. No breakdown or flashover occurs when 2kV AC withstand voltage is applied between live conductors and the enclosure for 1 minute, ensuring an ample safety insulation margin.
Key Safety Operation Tips
Must connect reliable protective earth before use; check the integrity of the grounding wire regularly.
Keep all socket rubber covers closed when not in use to prevent water ingress and short circuits.
Do not overload the box; total load current cannot exceed rated 16A.
Stop using immediately if cable, plug or enclosure is cracked, damaged or aged.

FAQ:
1.Can this distribution unit work with generator power supply? Will voltage fluctuation damage internal breakers?
Yes, it fully adapts to portable construction generators. Its internal circuit design features 450/750V rated insulation and 2kV withstand voltage margin, which can absorb instantaneous voltage surges generated during generator startup and unstable output. When generator voltage fluctuates between 200V–250V, the C-curve MCBs maintain normal protection function without false tripping or burnout. For generators with severe harmonic distortion, we recommend adding an optional external EMI filter as a customized accessory. This compatibility allows rental company.
2.What maintenance spare parts can be independently replaced without replacing the whole box?
All core wearing components are modular replaceable: MCB miniature circuit breakers, complete socket base assemblies, EPDM sealing gaskets, input industrial plugs, PG cable glands and side carry handles. No integral welding or sealed non-detachable structures are used. Maintenance staff only need to stock a small set of spare parts to repair damaged units on-site, cutting equipment scrappage rate and long-term procurement costs for contractors and rental companies.